The decoupled power splitter can be used:
– for power distribution, e. g. from one common
antenna to several receivers with frequency
spacing as narrow as desired,
– for power distribution, for example: from one
transmitter to several outputs,
– for decoupled combining of several transmitters
with frequency spacing as narrow as desired
(at 4.7 dB or 6 dB loss),
– for decoupled combining of several transmitting/
receiving units, whose integrated duplexers are
within the same frequency range.
Function
:
The decoupled 3:1
power splitter has 3 inputs, one
output,and 3 absorber ports. The decoupled 4:1
power splitter has 4 inputs, one output, and 4
absorber ports.The inputs are only decoupled if the
absorber ports are terminated with 50
O loads of
suitable power.
Dimensioning the external absorbers:
The absorbers of the
3:1
power splitter must be
dimensioned so that at least 2/3 of the power fed
into the inputs can be absorbed.
Example: If a power of 50 W is fed into every input,
then the absorbers must be able to absorb 33 W
each.
The absorbers of the
4:1
power splitter must be
dimensioned so that at least 3/4 of the power fed
into the inputs can be absorbed.
Example: If a power of 50 W is fed into every input,
then the absorbers must be able to absorb 37 W